Why is my aircon not cold but still blowing air?
Short answer
An aircon that still blows air but is not cold is usually losing heat transfer, not airflow: a soiled coil or blower, a blocked outdoor condenser, or low refrigerant from a leak. In Singapore, a gas top-up alone does not fix a leak — a pressure test and leak check come first.
Updated 12 Nov 2026 · AOT Aircon, the air-conditioning trade site of ALPHA & OMEGA TRINITY PTE. LTD. (UEN 201215586K), BCA ME01 Grade L1 to 1 Sep 2028.
Symptom, likely cause, and what a technician checks
The useful test is the air temperature split: a healthy split unit supplies air roughly 8–10°C colder than the air it draws in. If the split is small, the fault is in the refrigerant circuit. If the split is normal but the room still does not cool, the unit is undersized or the heat is coming from somewhere else.
| What you notice | Likely cause | What we check |
|---|---|---|
| Air comes out but the room stays warm | Soiled coil or blower wheel blocking heat transfer | Coil face and blower condition, supply and return air temperatures |
| Cold for 10–15 minutes, then warm again | Low refrigerant, or ice building on the coil and pipes | Operating pressure and superheat, ice on coil, filter condition |
| One room cold, another never cools | Blocked or kinked pipe run, faulty valve, or an undersized indoor unit | Pressure and pipe run per indoor unit, not just the outdoor unit |
| Outdoor unit starts then cuts out quickly | Dirty condenser, compressor overload or a failing capacitor | Condenser coil wash, compressor amp draw against nameplate, capacitor test |
| Cooling only at night or early morning | Undersized unit or poor outdoor ventilation in the afternoon heat | Capacity against room heat load, clearance and airflow around the condenser |
| Set to 16°C but the display reads 25°C | Faulty thermistor, wrong mode, or a filter so clogged the coil never gets cold | Sensor reading against a real thermometer, mode check, filter and coil |
A chemical wash cleans the indoor coil in place; it does not add refrigerant and it will not fix a leak. If your symptom is water dripping rather than warm air, the chemical wash vs chemical overhaul guide covers that separately.
How much is aircon gas top-up — and is it a fix?
AOT charges from S$80 per unit for a gas top-up, before 9% GST, and only after a pressure and leak check. A split system in Singapore is sealed: it does not burn refrigerant, so if the charge is low, gas is escaping through a joint, coil or valve. Topping up without finding that leak just buys weeks.
| What you notice | What it usually means | What we do before quoting |
|---|---|---|
| Cooling comes back for a few weeks, then fades again | Refrigerant is escaping — the top-up treated the symptom, not the leak | Nitrogen pressure test, then trace the flare joint, coil or valve |
| Ice on the indoor coil or the outdoor valve | Low charge, or restricted airflow — the two look identical | Airflow and coil condition first, then pressure and superheat |
| Someone topped up without weighing the charge | Overcharged or undercharged — both reduce cooling | Recover, vacuum, then recharge to the nameplate weight in grams |
| Outdoor pipe never cold, never sweating | Very low charge, or a blocked capillary / expansion valve | High and low side pressures, then check for the restriction |
| Same unit topped up three times in two years | Corroded coil or a leaking flare that nobody traced | Cost the repair against replacement before adding more gas |
| One room warm, the others cold | A pipe run, valve or indoor unit — not the system charge | Pressure at each indoor unit, not just the outdoor unit |
Send the model label and a photo of the outdoor unit. We pressure test first. If the circuit holds, we tell you gas is not your problem and you do not pay for a top-up. If it does not hold, you get the leak location and a repair price before any refrigerant goes in.
Gas top-up from S$80 per unit is labour and refrigerant for a standard wall-mounted split, confirmed before work. The refrigerant type and charge weight come from the unit nameplate, not a guess.
What happens when you engage AOT
- Send photos. Indoor unit, model label, outdoor unit and the filter. Tell us the unit count and whether the unit ever ices over.
- Survey, then quote. We attend, measure the air split and pressures, and tell you the cause in plain words with a from-price before any work starts. Nothing is dismantled before you agree.
- Fix in the right order. Clean what is clogged, then test. If pressure is low, we look for the leak instead of topping up again. Parts and refrigerant are quoted separately.
- Prove it before we leave. Air split re-measured at the indoor unit, drain checked for flow, and you get the reading, not just a receipt.
Hours are Monday to Saturday 08:00–17:00, closed Sunday and public holidays. We are not a 24-hour service; after-hours WhatsApp is logged for the next window.
Questions we get asked
Why is my aircon blowing air but not cold?
An aircon that still blows air but is not cold is usually losing heat transfer, not airflow: a soiled coil or blower, a blocked outdoor condenser, or low refrigerant from a leak. In Singapore, a gas top-up alone does not fix a leak — a pressure test and leak check come first.
Is an aircon gas top-up enough to fix it?
Only if refrigerant was genuinely low and the circuit holds pressure. If the unit loses cooling again weeks after a top-up, gas is escaping somewhere. We check pressure and for leak traces first, then quote the repair instead of selling repeat top-ups. Gas top-up starts from S$80 per unit.
How do I tell a dirty coil from low gas?
Weak airflow with a grey or black coil points to a soiled coil and blower — that is cleaning work. Strong airflow that is only slightly cool, with ice forming on the coil or pipes, points to low refrigerant or a restriction.
How much does diagnosis and cleaning cost in Singapore?
General servicing starts from S$25 per unit and a chemical wash from S$80 per unit, confirmed before work starts. If a leak is found, repair is quoted after the pressure test — not bundled into a top-up. Parts and refrigerant are extra.
Can you attend today?
We work Monday to Saturday 08:00–17:00 and we are not a 24/7 service. Send unit count, the symptom and photos on WhatsApp 8151 8857 (text only) for a from-price and a booking slot.
How much is an aircon gas top-up in Singapore?
From S$80 per unit at AOT, before 9% GST, and only after a pressure and leak check. A standard wall-mounted split is the reference unit; refrigerant type and charge weight come off the nameplate. If the circuit holds pressure you do not need gas, and we say so instead of charging for it.
Is a gas top-up a permanent fix?
No. A sealed split system does not consume refrigerant, so low gas means gas is escaping. A top-up restores cooling for weeks or months and then the same fault returns. The permanent fix is finding the leak — usually a flare joint, coil or valve — repairing it, and recharging to the nameplate weight.
How long does an aircon gas top-up last?
On a sound circuit, a correctly charged unit holds its refrigerant for years. If cooling fades within one season, gas is still escaping and the leak has not been found. That is why we test before charging, so you are not buying the same top-up twice.
Send a photo, get a from-price
ALPHA & OMEGA TRINITY PTE. LTD. (UEN 201215586K) · 32 Old Toh Tuck Road, I. Biz Centre #03-11, Singapore 597658 · BCA ME01 Grade L1 to 1 Sep 2028 · bizSAFE Level 3 (E18947) valid to 27 Jul 2029.
[email protected] · Mon–Sat 08:00–17:00, closed Sunday and public holidays
Related: chemical wash vs overhaul · all aircon services · aircon servicing cost on the company hub